Analysis Modeler

Activating - Deactivating Images


This use case shows you how to change activation status of image.

The macro opens an Analysis document which already contains a computed Frequency case and image. The activation status of "Translational displacement vector.1" image is changed.

 

 

CAAAniPostProAcDesact is launched in CATIA [1]. No open document is needed.

CAAAniPostProAcDesact.catvbs is located in the CAAScdAniUseCases module. Execute macro (Windows only).

 

CAAAniPostProAcDesact includes the following steps:

  1. Prolog
  2. Retrieve Analysis Cases and Analysis Sets from the Analysis Document
  3. Changing the Activation Status
  4. Epilog

Prolog

...
' ----------------------------------------------------------- 
' Optional: allows to find the sample wherever it's installed
  sDocPath=CATIA.SystemService.Environ("CATDocView")

    If (Not CATIA.FileSystem.FolderExists(sDocPath)) Then
      Err.Raise 9999,,"No Doc Path Defined"
    End If
' ----------------------------------------------------------- 
' Open the Analysis document 
sFilePath = CATIA.FileSystem.ConcatenatePaths(sDocPath, "online\CAAScdAniUseCases\samples\Cube_R13_Freq.CATAnalysis")
Set oAnalysisDocument = CATIA.Documents.Open(sFilePath)
...

Open the Analysis document. The Analysis document is retrieved in the documentation installation path, this path has already been stored in the sDocPath variable. In the collection of documents, two documents can be retrieved; the Analysis document and the Part document.

Retrieve Analysis Cases and Analysis Sets from Analysis Document

...
' Retrieve the Analysis Manager
Set oAnalysisManager = oAnalysisDocument.Analysis
			
' Retrieve the analysis model from the list of models
Set oAnalysisModels = oAnalysisManager.AnalysisModels
Set oAnalysisModel = oAnalysisModels.Item(1)
' Retrieve the analysis cases and the first analysis case
Set oAnalysisCases = oAnalysisModel.AnalysisCases
Set oAnalysisCase = oAnalysisCases.Item(1)
' Retrieve the analysis cases and the Frequency case solution
Set oAnalysisSets = oAnalysisCase.AnalysisSets
Set oAnalysisSet = oAnalysisSets.Item("Frequency Case Solution.1", catAnalysisSetSearchAll)
Set analysisImages1 = oAnalysisSet.AnalysisImages
...

According to the general Analysis Document structure, this macro uses some standard procedures to navigate or retrieve the required objects. First, from the Document, we find the Analysis Manager Object, the Analysis Model.

The Analysis case is retrieved from list of cases by its index. The model contains only one analysis case hence we pass 1 to the method Item. Otherwise we pass the appropriate index of the desired analysis case if there are more Analysis cases. The analysis case is retrieved from the list of image by its name. The name is same as that appears in the tree, in the interactive environment.

Changing the Activation Status

...  
'activation of an  image
'==============
'we search image Disp_Symbol
Set oAnalysisImage = analysisImages1.Item("Disp_Symbol")

'we Activate the image
oAnalysisImage.SetActivationStatus true

'we update the  image
oAnalysisImage.Update

'deactivation of an  image
'===============
'we deactivate the image
oAnalysisImage.SetActivationStatus false

'we update the  image
oAnalysisImage.Update
...

Epilog

...
End Sub
...

To run the macro interactively CATDocView environment variable must be defined.

[Top]


In Short

This use case has shown how to change the activation status of an image.

[Top]


References

[1]Replaying a Macro
[Top]